AMF Panel for Honda EU70iS, 63 Amp PMC, Three Phase
Three phase power backup, fully automatic, built for the Honda EU70iS.
Get Best Price- Panel Type
- AMF Panel (PMC Technology)
- Compatible Genset
- Honda EU70iS (5.5 kVA rated / 7.0 kVA max)
- Current Rating
- 63 Amp, Three Phase
- Operating Voltage
- 12VDC control · 130–280 VAC
Subtech's PMC AMF Panel is a 63 Amp, three-phase Auto Mains Failure panel purpose-built for the Honda EU70iS (5.5 kVA rated / 7.0 kVA max) petrol inverter generator. It handles three-phase mains input with single-phase generator output, auto-starting on mains failure and switching back seamlessly when power restores.
What is the AMF Panel for Honda EU70iS?
The Subtech PMC AMF Panel for Honda EU70iS is a 63 Amp, three-phase Auto Mains Failure panel that auto-starts the Honda EU70iS petrol inverter generator (5.5 kVA rated, 7.0 kVA max) on mains failure and auto-stops it when mains power restores. It handles three-phase mains input with single-phase generator output, and is available in 3-Pole and 4-Pole (full neutral isolation) configurations. The 4-Pole version is recommended for hospitals, data centers and other sensitive-load sites.
Key Specifications at a Glance
Quick reference before you scroll through the full spec sheet
Why Choose AMF Panel for Honda EU70iS, 63 Amp PMC, Three Phase?
What actually matters when you put this on your line
PMC Technology
1-second contactor activation eliminates chattering and coil burning, even across the wider 130-280VAC band this panel is rated for.
Sized for the Honda EU70iS
Tested against the Honda EU70iS's full 7.0 kVA max output, not a generic AMF relay repurposed for a bigger genset.
3-Pole and 4-Pole Options
Choose 3-Pole for standard three-phase switching, or 4-Pole for full neutral isolation on sensitive loads.
Three Phase Mains, Single Phase Genset Output
Correctly handles the mismatch between three-phase mains input and the Honda EU70iS's single-phase generator output.
Inbuilt Battery Charger
Keeps the Honda EU70iS starter battery ready so the genset starts reliably on every mains failure.
3 Cranking Attempts
Retries starting at 15-second intervals if the first attempt doesn't catch.
Audio-Visual Fault Alarm
Flags genset faults immediately with both a visual and audible alert.
Rust-Resistant Enclosure
Powder-coated GI box, wall-mounted, compact, built for Indian site conditions.
Description▾
Built on Subtech's PMC (Pre Magnetic Contactor) technology, the contactor coil energises for just 1 second per switch, eliminating the chattering and coil-burning that plague conventional AMF relays, even across the wider 130-280VAC operating band this panel supports. Available in 3-Pole (line-only switching) and 4-Pole (full neutral isolation, recommended for hospitals and data centers) configurations.
Subtech's PMC AMF Panel is a 63 Amp, three-phase Auto Mains Failure panel purpose-built for the Honda EU70iS (5.5 kVA rated / 7.0 kVA max) petrol inverter generator. It handles three-phase mains input with single-phase generator output, auto-starting on mains failure and switching back seamlessly when power restores.
Additional Information▾
- Auto Start and Auto Stop genset on mains failure and restoration
- Three phase mains input with single phase generator output
- 4-Pole option gives full isolation of mains and generator supply
- Inbuilt battery charger keeps genset battery always ready
- Audio-visual alarm on genset faults
- Auto and Manual mode with remote operation provision
- 3 cranking attempts at 15 sec intervals for reliable starting
- PMC technology, no chattering, no coil burning, smooth switching
Technical Specifications
| Capacity | 63 Amp |
| Phase | Three Phase |
| Voltage | 12VDC, 130-280VAC |
| For Generator | Honda EU70iS |
| Configuration | 3-Pole / 4-Pole |
| Technology | PMC (Pre Magnetic Contactor) |
| Enclosure | Powder-coated GI, wall-mount |
Who Should Buy AMF Panel · Honda EU70iS?
This product is ideal for the following users and industries
Industrial Units & Factories
Manufacturing plants needing reliable auto-backup from a petrol generator when mains fail.
Agricultural & Farming
Farms, dairies and poultry needing critical loads to keep running on Honda gensets without manual switching.
Contractors & Builders
Site offices, construction zones and temporary installations needing hands-free backup.
Commercial Establishments
Hotels, hospitals, offices and shops needing uninterrupted operation during power cuts.
Applications & Use Cases
Where you can use AMF Panel · Honda EU70iS effectively
Auto-backup for Honda EU70iS petrol generators
Hospitals and data centers (use 4-Pole model for neutral switching)
Commercial establishments needing three-phase backup
Site offices and remote installations with unreliable mains
Generator-mains transfer for mid-size industries
Frequently Asked Questions
Common questions about AMF Panel · Honda EU70iS
What is the warranty on the AMF Panel for Honda EU70iS?▾
12 months from date of invoice against manufacturing defects, covering all electronic components and the enclosure.
Should I choose 3-Pole or 4-Pole?▾
3-Pole switches the three line conductors. 4-Pole also switches the neutral, fully isolating mains and generator supplies, the safer option for hospitals, data centers and sensitive electronic equipment.
Can I get a customised version?▾
Yes, current rating, voltage cutoffs and panel size can be customised for bulk orders. Contact our sales team with your requirement.
What is the delivery time?▾
Standard models ship within 3-5 working days. Customised panels take 10-15 working days depending on the BOM.
Is installation support available?▾
Yes. Our service team supports installation through certified electricians across India, plus remote commissioning guidance.
Can I buy this in bulk for a project?▾
Absolutely. Project / dealer pricing is available for quantities above 10 units. Share your single-line diagram or load list and we will quote within 24 hours.
Downloads
Technical documentation for this model
Related Products
Related Technical Articles
- What Is a Motor Starter? Function, Types & Working
- AMF vs ATS: What's the Difference?Coming soon
Applicable Standards & Design Considerations
- Honda Power Products Authorised Partner: Subtech has been an authorised automation partner for Honda Power Products in India since 2007, designing and testing panels specifically for the EU30iS and EU65iS/EU70iS petrol inverter generator range.
- IS/IEC 60529: Enclosure ingress protection reference. Subtech's powder-coated GI panel enclosures are built for outdoor/site conditions typical of Indian installations.