Protect Karo.

Free technical education for electricians, dealers, farmers and engineers. From error code lookup to motor ROI calculators, everything in one place.

4+
Tools Available
Free
Always Free
25+
Years Experience
About Pathshala

Everything You Need to Know.
All in One Place.

Motor jali kyu? Panel kab badalna chahiye? Kaunsa contactor sahi hai? Subtech ki Pathshala mein sab milega — free of cost.

đŸŽŦ
Video Tutorials
subtech ke saath real panel education. Motor protection ke secrets explained simply.
🔍
Error Code Lookup
Type any MPU fault code, get cause and fix instantly. No manual needed.
🧮
Calculators
HP to kW, full load current, ROI calculator, panel type selector.
📚
Glossary
Simple definitions for every electrical term in Hindi and English. 20+ terms.

Motor Protection Ki
Real Education.

subtech seedha explain karte hain - kyu motor jalti hai, aur kaise bachate hain. Field se seedha aap tak.

Motor Protection
Motor Kyu Jalti Hai?
Real reasons behind motor failure in India. From single phasing to overloading — understand the root causes and how Subtech panels prevent them.
S
Subtech  ¡  Instagram Reel
📷 View on Instagram →
Panel Selection
Sahi Panel Kaise Chunein? Complete Guide
DOL, Star-Delta, ya VFD — kaunsa panel aapke motor ke liye sahi hai? subtech ka simple explanation with real product examples.
S
Subtech  ¡  Instagram Reel
📷 View on Instagram →
Electrical Safety
Panel Ke Andar Kya Hota Hai?
Inside a Subtech panel — components, quality, and why cheap panels fail. A direct explanation from the subtech with real product visuals.
S
Subtech  ¡  Instagram Reel
📷 View on Instagram →

Aur videos dekhne ke liye Instagram follow karo

@subtech.in - Follow on Instagram
Instant Tool

MPU Error Code Lookup

Panel mein red light aayi? Error code dekha? Type karo neeche — cause aur fix second mein milega.

Error Code Finder

Konsa Error Aaya?

Common codes — click to try:
E01E02E03E04E05E06OLPFUVOVDRRP
Smart Tools

Engineer Ki Toolkit.
Sabke Liye Free.

HP se kW karo, cable size nikalo, ya dekho Subtech panel kitne mein recover ho jaata hai.

⚡
HP to kW Converter
Horsepower and kilowatt converter (both ways)
Result
7.46kW
10 HP = 7.46 kW. At 415V 3-phase, FLC approx. 12.2 A (at 0.85 PF).
⚡
Full Load Current (FLC)
Motor FLC for panel and cable sizing
Full Load Current
-Ampere
Enter motor HP to calculate FLC
📈
Subtech ROI Calculator
Kitne mein recover hoga panel — dekho
Enter motor HP and daily usage to see ROI
🔌
Panel Type Selector
Kaunsa panel sahi hai aapke motor ke liye
Select HP and application type
Glossary

Electrical Terms
Simply Explained.

Technical words in simple Hindi and English. 20+ terms from the field.

DOL Starter
Direct Online Starter. Motor ko seedha supply se connect karta hai. Small motors (up to 7.5 HP) ke liye.
Star-Delta
Motor starting method for large motors (above 10 HP). Star mein start, delta mein run. Inrush current kam karta hai.
MPU
Motor Protection Unit. Subtech ka digital brain jo overload, phase fail, dry run sab detect karta hai.
PMC
Pre Magnetic Contactor. Subtech ka patented switch. Coil nahi jalti. 1000+ hours continuous run possible.
VFD
Variable Frequency Drive. Motor ki speed control karta hai frequency change karke. Energy efficient.
Overload
Jab motor rated current se zyada current kheenche. Motor overheat ho ke jal sakti hai.
Single Phasing
3-phase supply mein se ek phase band hona. Motor sirf 2 phase pe chale — bahut dangerous.
Dry Run
Pump bina paani ke chalti rahe. Motor overheat ho jaati hai. Subtech panel isko detect karke band kar deta hai.
AMF Panel
Automatic Mains Failure panel. Mains band hote hi DG automatically start ho jaata hai.
ATS
Automatic Transfer Switch. Power source switch karta hai — mains se DG ya solar pe automatically.
IP Rating
Ingress Protection. Panel ke enclosure ki rating. IP54 = dust protected and splash resistant.
Contactor
Electrically controlled switch for motors. AC coil se operate hota hai. Cheap ones jal jaate hain.
Thermal Relay (OLR)
Bimetallic strip se overload detect karta hai. Temperature ke saath accuracy change hoti hai — MPU better hai.
Busbar
Panel ke andar copper ka thick conductor. Current le jaata hai. Thin busbar = zyada heat = risk.
MCCB
Moulded Case Circuit Breaker. Short circuit pe automatically trip karta hai. MCB se zyada capacity.
Phase Sequence
3-phase mein phase ka order (R-Y-B). Wrong sequence se motor ulta ghoomta hai — motor damage ho sakti hai.
Voltage Unbalance
Teen phases mein voltage alag hona. 5% se zyada unbalance motor ke liye harmful hai.
Power Factor
Actual power aur apparent power ka ratio. Inductive loads (motors) ka PF low hota hai. APFC se improve hota hai.
APFC Panel
Automatic Power Factor Correction. Capacitors automatically connect/disconnect karke PF 0.95+ pe rakho.
MCC Panel
Motor Control Centre. Multiple motors ek hi panel se control aur protect karta hai.

Aur Kuch Sikhna Hai?

Call karo ya WhatsApp karo. Our technical team is available Mon-Sat, 9 AM to 6 PM.