Subtech LogoSince 1998
Kisan Series — Star Delta
Subtech Product

Kisan Series — Star DeltaThree Phase Motor Starter · Fully Automatic

Get Best Price
Model Type
Kisan Series — Star Delta · Three Phase Motor Starter
Operation
Fully Automatic · Smart Star Delta starter for large irrigation pumps
Rating Range
7.5 HP - 125 HP
Best Suited For
Star Delta · Submersible

Simple knob-based Star Delta starter built for large irrigation and agricultural pumps. Starting range: 7.5 HP.

What is Kisan Series — Star Delta?

Kisan Series — Star Delta is a fully automatic three phase motor starter panel from Subtech (S S Power System), covering 7.5 HP to 125 HP. It is part of Subtech's motor control solutions range and is commonly used for induction motors, pumps, compressors and other industrial and agricultural machinery. Protection features include single phasing, reverse phasing, phase unbalance cutoff, over voltage protection, under voltage protection, overload protection, short circuit protection, dry run protection (optional).

Key Specifications at a Glance

Quick reference before you scroll through the full spec sheet

Product Series
Kisan Series — Star Delta
Product Category
Motor Control Solutions
Operation
Fully Automatic
Starter Type
Star Delta / Submersible
Motor Phase
Three Phase
Rating Range
7.5 - 125 HP
Protection Type
Single Phasing, Reverse Phasing, Phase Unbalance Cutoff, Over Voltage Protection, Under Voltage Protection, Overload Protection, Short Circuit Protection, Dry Run Protection (Optional)
Best Suited For
Star Delta · Submersible
Available Models
14 models
Add-ons
3 available

Why Choose Kisan Series — Star Delta?

What actually matters when you put this on your line

Reduced Starting Current

Star-Delta switching lowers inrush current at start-up, protecting windings, cabling and upstream breakers.

Digital Monitoring

A digital display and settings make it easier to read status and adjust cut-offs without repeatedly opening the panel.

Multiple Motor Protections

Built-in protection against single phasing, reverse phasing, phase unbalance cutoff, over voltage protection reduces avoidable motor failures.

Wide HP Range

Covers 7.5 - 125 HP, so one series can standardise across multiple motor sizes on site.

Built for Industrial & Pump Applications

Designed for the duty cycles seen in pumps, compressors, HVAC systems and general industrial motor loads.

Custom Panel Manufacturing Support

Subtech can adapt enclosure size, ratings and add-ons to project-specific requirements on request.

Rust-Resistant, Field-Ready Enclosure

Powder-coated GI/GPSP enclosures are built for Indian site conditions — dusty factory floors, outdoor pump houses and agricultural sheds alike.

Backed by Subtech's Sales & Service Network

25+ years of panel manufacturing and a pan-India dealer network stand behind every unit.

How Kisan Series — Star Delta Works

Step-by-step operating sequence

  1. 1

    Motor Starts in Star Connection

    On the start command, the contactor connects the motor windings in Star, limiting inrush current.

  2. 2

    Starting Current Is Reduced

    The Star connection drops the line current to roughly a third of a direct-on-line start, reducing stress on the motor and supply.

  3. 3

    Timer/Control Logic Monitors the Transition

    An internal timer (or digital control logic on automatic models) tracks how long the motor has been running in Star.

  4. 4

    Starter Switches to Delta Connection

    Once the motor has picked up speed, the panel switches the winding connection to Delta for full running torque.

  5. 5

    Motor Runs at Full Load

    In Delta, the motor receives full line voltage across each winding and runs at rated output.

  6. 6

    Protection System Monitors Faults Continuously

    Single phasing, reverse phasing, voltage and overload protection continue monitoring the motor throughout the run.

How to Select the Correct Model

Match your motor's HP rating to the correct reference number

HPRef. No.kWRelay Range (A)ProtectionSize (mm)MRP
7.5 HPSDK75.510-25350*300*125₹21,600
10 HPSDK107.515-35350*300*125₹21,600
15 HPSDK151120-45350*300*125₹22,300
20 HPSDK201525-50350*300*125₹22,300
25 HPSDK2518.530-55350*300*125₹31,100
30 HPSDK30L2240-75350*300*125₹31,100
30 HPSDK302240-75450*500*170₹46,800
40 HPSDK403060-90450*500*170₹49,250
50 HPSDK503770-120450*500*170₹62,900
60 HPSDK604580-140450*500*170₹62,900
75 HPSDK755690-150550*450*130₹79,500
85 HPSDK8560120-185550*450*130On Request
100 HPSDK1007570-120 (H)On Request
125 HPSDK1259280-140 (H)On Request

Common Problems This Solves

Real failure modes on the motor side, and how this panel prevents them

High Starting Current

Star-Delta switching reduces inrush current at start-up compared to a direct-on-line start, easing stress on the motor, cabling and upstream breakers.

Motor Overheating

Sustained overload, phase and voltage faults raise winding temperature over time; the panel's built-in protections cut power before heat damages the insulation.

Single Phasing

Detects the loss of any one phase and cuts power before the motor overheats or burns its windings.

Reverse Phase Sequence

Checks phase sequence before allowing the motor to start, preventing motors and pumps from running backward.

Voltage/Phase Imbalance

Trips the motor when the three phases drift too far apart in voltage, which otherwise causes uneven heating in the windings.

Over-Voltage Spikes

Cuts power when supply voltage rises above the safe band, protecting insulation and electronics.

Under-Voltage / Low Supply

Cuts power when voltage drops too low, preventing the motor from drawing excess current to compensate.

Motor Overload

Monitors running current and trips before sustained overload can overheat the motor.

Short Circuit / Wiring Fault

MCB/MCCB protection isolates the circuit immediately on a short circuit, protecting the panel and wiring.

Dry Running (Pump Losing Prime)

Optional dry-run protection stops the motor when there's no load/flow, preventing pump damage from running dry.

Frequent Tripping From Wrong Model Selection

Use the selection guide above to match your motor's HP and relay range to the correct reference number — an undersized relay setting is a common cause of nuisance tripping.

Description

Simple knob-based Star Delta starter built for large irrigation and agricultural pumps. Starting range: 7.5 HP.

Additional Information
  • Wide operating Voltage range: 240-480 VAC
  • Continuous running capacity: 100+ hrs
  • Status: R-Y-B Phases, Healthy Power, Run Hr.
  • Faults: Phase fail, Reverse Phase, Unbalance Voltage, Over/Under Voltage, Overload
  • PMC Contactor for smooth, fast switching (5 years warranty on contactor coil against burning)
  • Body: Rust-free GPSP Sheet, Wall mounting, compact size
  • Heavy duty DMC connection terminals for input and output
  • Site settable overload cut-off (by knob)
  • Fixed over & under voltage cut-off
  • Smart digital display interface
  • Rust-free GPSP/GI sheet enclosure
  • Heavy Duty DMC Power Terminal

Models & Pricing

14 models
Ref. No.HPkWRelay Range (A)Size (mm)Wt. (kg)MRPStd. Pack
SDK77.55.510-25350*300*1255.5₹21,6006
SDK10107.515-35350*300*1255.5₹21,6006
SDK15151120-45350*300*1255.5₹22,3006
SDK20201525-50350*300*1255.5₹22,3006
SDK252518.530-55350*300*1256.0₹31,1005
SDK30L302240-75350*300*1256.0₹31,1005
SDK30302240-75450*500*1706.0₹46,8003
SDK40403060-90450*500*1709.0₹49,2503
SDK50503770-120450*500*17015.0₹62,9003
SDK60604580-140450*500*17015.0₹62,9003
SDK75755690-150550*450*13022.0₹79,5003
SDK858560120-185550*450*13022.0On Request
SDK1001007570-120 (H)On Request
SDK1251259280-140 (H)On Request
Prices are MRP in INR, ex-GST and ex-installation. Specifications subject to change without notice.

Protections

  • Single Phasing
  • Reverse Phasing
  • Phase Unbalance Cutoff
  • Over Voltage Protection
  • Under Voltage Protection
  • Overload Protection
  • Short Circuit Protection
  • Dry Run Protection (Optional)

Add-ons

  • Dry Run Charges: ₹890 charged extra
  • Double tank operation: ₹1400 charged extra
  • Sensor Set: ₹1380 charged extra

Who Should Buy Kisan Series — Star Delta?

This product is ideal for the following users and industries

🏭

Industrial Units & Factories

Manufacturing plants, processing units, and industrial facilities requiring reliable motor control and automation solutions.

🌾

Agricultural & Farming

Farmers and agricultural businesses using water pumps, irrigation systems, and motor-driven equipment for daily operations.

🏗️

Contractors & Builders

Electrical contractors, panel builders, and construction professionals who need dependable motor starting solutions.

🏢

Commercial Establishments

Hotels, hospitals, offices, and commercial buildings with HVAC, lift, and pump motor control requirements.

Applications & Use Cases

Where you can use Kisan Series — Star Delta effectively

1

Water Pump Motor Control

Submersible, centrifugal, and booster pump motor starting, protection, and automation for residential and commercial use.

2

Compressor & HVAC Systems

Air compressors, chillers, and HVAC blower motor control in factories, commercial buildings, and cold storage units.

3

Conveyor & Material Handling

Belt conveyors, rollers, and material handling equipment motors used in manufacturing and logistics.

4

Irrigation & Agriculture

Drip irrigation, sprinkler systems, and tube well motors for farms and agricultural land management.

5

Generator & ATS Panels

Auto transfer switch panels and generator motor control for seamless power backup solutions.

6

CNC & Machine Tools

Lathe machines, drilling machines, and CNC equipment requiring precise motor starting and protection.

Frequently Asked Questions

Common questions about Kisan Series — Star Delta

What is the warranty on Kisan Series — Star Delta?

Subtech provides a standard manufacturer warranty on this product. Warranty terms may vary based on the specific model and configuration. Contact our sales team for detailed warranty information.

Can I get a customized version of Kisan Series — Star Delta?

Yes, Subtech specializes in custom panel manufacturing. We can modify specifications, ratings, enclosure types, and features as per your specific requirements. Share your needs through the quote form above.

What is the delivery time?

Standard models are typically available within 3-5 working days. Customized configurations may take 7-15 working days depending on complexity. We deliver across India.

Is installation support available?

Yes, Subtech provides installation guidance and technical support. For bulk orders, on-site commissioning support is also available. Our service team can assist with wiring diagrams and configuration.

Can I buy this product in bulk for my project?

Absolutely. We offer competitive bulk pricing for dealers, distributors, contractors, and project orders. Request a quote with your quantity for the best price.

Kisan Series — Star Delta vs Conventional Star Delta Starter

See exactly what the automation adds over a conventional starter

FeatureKisan Series — Star DeltaConventional Starter
OperationFully automatic, digital soft-switch settingsManual or basic electromechanical timer relay
Protection8 built-in protectionsTypically overload/MCB protection only
AutomationYes — timer/control logic manages the full start sequenceManual timer relay, no digital control logic
External CommandNot standard on this modelNot supported
Display / MonitoringDigital displayAnalog meters or none
Phase Failure ProtectionIncludedUsually not included
Reverse Phase ProtectionIncludedUsually not included
Voltage MonitoringOver/under voltage cutoffUsually not included
Dry Run ProtectionAvailable as an add-onNot available
MaintenanceLow — solid-state switching, PMC contactorHigher — mechanical timer relay wears over time
CustomizationSubtech offers custom panel manufacturing on requestTypically fixed configuration

Downloads

Technical documentation for this model

DatasheetAvailable on request
CatalogueAvailable on request
Wiring DiagramAvailable on request
Installation ManualAvailable on request
Technical SpecificationsAvailable on request

Related Products

Related Technical Articles

Applicable Standards & Design Considerations

  • IEC/IS 60947: Low-voltage switchgear and controlgear — general design reference for contactors, starters and protective devices, where applicable to the components used.
  • IS/IEC 60529: Enclosure ingress protection (IP) ratings — referenced for enclosure design where an IP rating is specified for a given model.