Kisan Series — DOLThree Phase Motor Starter · Fully Automatic
Get Best Price- Model Type
- Kisan Series — DOL · Three Phase Motor Starter
- Operation
- Fully Automatic · Smart DOL starter, knob-based, for everyday agricultural use
- Rating Range
- 1 HP - 30 HP
- Best Suited For
- DOL · Submersible
Simple knob-based starter built for everyday agricultural use. Available range: 1 to 30 HP.
What is Kisan Series — DOL?
Kisan Series — DOL is a fully automatic three phase motor starter panel from Subtech (S S Power System), covering 1 HP to 30 HP. It is part of Subtech's motor control solutions range and is commonly used for induction motors, pumps, compressors and other industrial and agricultural machinery. Protection features include single phasing, reverse phasing, phase unbalance cutoff, over voltage protection, under voltage protection, overload protection, short circuit protection, dry run protection (optional).
Key Specifications at a Glance
Quick reference before you scroll through the full spec sheet
Why Choose Kisan Series — DOL?
What actually matters when you put this on your line
Digital Monitoring
A digital display and settings make it easier to read status and adjust cut-offs without repeatedly opening the panel.
Multiple Motor Protections
Built-in protection against single phasing, reverse phasing, phase unbalance cutoff, over voltage protection reduces avoidable motor failures.
Wide HP Range
Covers 1 - 30 HP, so one series can standardise across multiple motor sizes on site.
Built for Industrial & Pump Applications
Designed for the duty cycles seen in pumps, compressors, HVAC systems and general industrial motor loads.
Custom Panel Manufacturing Support
Subtech can adapt enclosure size, ratings and add-ons to project-specific requirements on request.
Rust-Resistant, Field-Ready Enclosure
Powder-coated GI/GPSP enclosures are built for Indian site conditions — dusty factory floors, outdoor pump houses and agricultural sheds alike.
Backed by Subtech's Sales & Service Network
25+ years of panel manufacturing and a pan-India dealer network stand behind every unit.
How Kisan Series — DOL Works
Step-by-step operating sequence
- 1
Start Command Given
Pressing start (or an auto signal) energises the main contactor directly.
- 2
Motor Connects Directly to Full Line Voltage
The motor windings are connected straight across the supply — no reduced-voltage stage.
- 3
Motor Accelerates to Full Speed
The motor draws a higher inrush current for a short period while it comes up to speed.
- 4
Motor Runs at Full Load
Once up to speed, the motor runs at its rated current under normal load.
- 5
Protection System Monitors Faults Continuously
Overload, short-circuit and (where fitted) phase protection continue monitoring the motor throughout the run.
How to Select the Correct Model
Match your motor's HP rating to the correct reference number
| HP | Ref. No. | kW | Relay Range (A) | Protection | Size (mm) | MRP |
|---|---|---|---|---|---|---|
| 1 HP | DK1 | 0.75 | 2-10 | — | 280*205*110 | ₹10,500 |
| 5 HP | DK5 | 3.7 | 5-20 | — | 280*205*110 | ₹10,500 |
| 7.5 HP | DK7L | 5.5 | 10-25 | — | 280*205*110 | ₹10,500 |
| 10 HP | DK10L | 7.5 | 10-30 | — | 280*205*110 | ₹10,500 |
| 7.5 HP | DK7 | 5.5 | 10-25 | — | 280*205*110 | ₹11,700 |
| 10 HP | DK10 | 7.5 | 15-35 | — | 280*205*110 | ₹11,700 |
| 12.5 HP | DK12 | 9.3 | 20-40 | — | 280*205*110 | ₹12,000 |
| 15 HP | DK15 | 11 | 20-45 | — | 310*250*120 | ₹13,100 |
| 20 HP | DK20 | 15 | 25-50 | — | 310*250*120 | ₹16,400 |
| 30 HP | DK30 | 22 | 40-75 | — | 450*400*130 | ₹19,100 |
Common Problems This Solves
Real failure modes on the motor side, and how this panel prevents them
Motor Overheating
Sustained overload, phase and voltage faults raise winding temperature over time; the panel's built-in protections cut power before heat damages the insulation.
Single Phasing
Detects the loss of any one phase and cuts power before the motor overheats or burns its windings.
Reverse Phase Sequence
Checks phase sequence before allowing the motor to start, preventing motors and pumps from running backward.
Voltage/Phase Imbalance
Trips the motor when the three phases drift too far apart in voltage, which otherwise causes uneven heating in the windings.
Over-Voltage Spikes
Cuts power when supply voltage rises above the safe band, protecting insulation and electronics.
Under-Voltage / Low Supply
Cuts power when voltage drops too low, preventing the motor from drawing excess current to compensate.
Motor Overload
Monitors running current and trips before sustained overload can overheat the motor.
Short Circuit / Wiring Fault
MCB/MCCB protection isolates the circuit immediately on a short circuit, protecting the panel and wiring.
Dry Running (Pump Losing Prime)
Optional dry-run protection stops the motor when there's no load/flow, preventing pump damage from running dry.
Frequent Tripping From Wrong Model Selection
Use the selection guide above to match your motor's HP and relay range to the correct reference number — an undersized relay setting is a common cause of nuisance tripping.
Description▾
Simple knob-based starter built for everyday agricultural use. Available range: 1 to 30 HP.
Additional Information▾
- Wide operating Voltage range: 240-480 VAC
- Continuous running capacity: 100+ hrs
- Status: R-Y-B Phases, Healthy Power, Run Hr.
- Faults: Phase fail, Reverse Phase, Unbalance Voltage, Over/Under Voltage, Overload
- PMC Contactor for smooth, fast switching (5 years warranty on contactor coil against burning)
- Body: Rust-free GPSP Sheet, Wall mounting, compact size
- Heavy duty DMC connection terminals for input and output
- Site settable overload cut-off (by knob)
- Fixed over & under voltage cut-off
- Smart digital display interface
- Rust-free GPSP/GI sheet enclosure
- Heavy Duty DMC Power Terminal
Models & Pricing
10 models| Ref. No. | HP | kW | Relay Range (A) | Size (mm) | Wt. (kg) | MRP | Std. Pack |
|---|---|---|---|---|---|---|---|
| DK1 | 1 | 0.75 | 2-10 | 280*205*110 | 3.0 | ₹10,500 | 5 |
| DK5 | 5 | 3.7 | 5-20 | 280*205*110 | 3.0 | ₹10,500 | 5 |
| DK7L | 7.5 | 5.5 | 10-25 | 280*205*110 | 3.0 | ₹10,500 | 5 |
| DK10L | 10 | 7.5 | 10-30 | 280*205*110 | 3.0 | ₹10,500 | 5 |
| DK7 | 7.5 | 5.5 | 10-25 | 280*205*110 | 3.5 | ₹11,700 | 5 |
| DK10 | 10 | 7.5 | 15-35 | 280*205*110 | 3.5 | ₹11,700 | 5 |
| DK12 | 12.5 | 9.3 | 20-40 | 280*205*110 | 3.5 | ₹12,000 | 5 |
| DK15 | 15 | 11 | 20-45 | 310*250*120 | 5.0 | ₹13,100 | 3 |
| DK20 | 20 | 15 | 25-50 | 310*250*120 | 5.0 | ₹16,400 | 3 |
| DK30 | 30 | 22 | 40-75 | 450*400*130 | 8.0 | ₹19,100 | 2 |
Protections
- Single Phasing
- Reverse Phasing
- Phase Unbalance Cutoff
- Over Voltage Protection
- Under Voltage Protection
- Overload Protection
- Short Circuit Protection
- Dry Run Protection (Optional)
Add-ons
- Dry Run Charges: ₹890 charged extra
- Double tank operation: ₹1400 charged extra
- Sensor Set: ₹1380 charged extra
Who Should Buy Kisan Series — DOL?
This product is ideal for the following users and industries
Industrial Units & Factories
Manufacturing plants, processing units, and industrial facilities requiring reliable motor control and automation solutions.
Agricultural & Farming
Farmers and agricultural businesses using water pumps, irrigation systems, and motor-driven equipment for daily operations.
Contractors & Builders
Electrical contractors, panel builders, and construction professionals who need dependable motor starting solutions.
Commercial Establishments
Hotels, hospitals, offices, and commercial buildings with HVAC, lift, and pump motor control requirements.
Applications & Use Cases
Where you can use Kisan Series — DOL effectively
Water Pump Motor Control
Submersible, centrifugal, and booster pump motor starting, protection, and automation for residential and commercial use.
Compressor & HVAC Systems
Air compressors, chillers, and HVAC blower motor control in factories, commercial buildings, and cold storage units.
Conveyor & Material Handling
Belt conveyors, rollers, and material handling equipment motors used in manufacturing and logistics.
Irrigation & Agriculture
Drip irrigation, sprinkler systems, and tube well motors for farms and agricultural land management.
Generator & ATS Panels
Auto transfer switch panels and generator motor control for seamless power backup solutions.
CNC & Machine Tools
Lathe machines, drilling machines, and CNC equipment requiring precise motor starting and protection.
Frequently Asked Questions
Common questions about Kisan Series — DOL
What is the warranty on Kisan Series — DOL?▾
Subtech provides a standard manufacturer warranty on this product. Warranty terms may vary based on the specific model and configuration. Contact our sales team for detailed warranty information.
Can I get a customized version of Kisan Series — DOL?▾
Yes, Subtech specializes in custom panel manufacturing. We can modify specifications, ratings, enclosure types, and features as per your specific requirements. Share your needs through the quote form above.
What is the delivery time?▾
Standard models are typically available within 3-5 working days. Customized configurations may take 7-15 working days depending on complexity. We deliver across India.
Is installation support available?▾
Yes, Subtech provides installation guidance and technical support. For bulk orders, on-site commissioning support is also available. Our service team can assist with wiring diagrams and configuration.
Can I buy this product in bulk for my project?▾
Absolutely. We offer competitive bulk pricing for dealers, distributors, contractors, and project orders. Request a quote with your quantity for the best price.
Kisan Series — DOL vs Conventional DOL Starter
See exactly what the automation adds over a conventional starter
| Feature | Kisan Series — DOL | Conventional Starter |
|---|---|---|
| Operation | Fully automatic, digital soft-switch settings | Manual or basic electromechanical timer relay |
| Protection | 8 built-in protections | Typically overload/MCB protection only |
| Automation | Yes — timer/control logic manages the full start sequence | Manual timer relay, no digital control logic |
| External Command | Not standard on this model | Not supported |
| Display / Monitoring | Digital display | Analog meters or none |
| Phase Failure Protection | Included | Usually not included |
| Reverse Phase Protection | Included | Usually not included |
| Voltage Monitoring | Over/under voltage cutoff | Usually not included |
| Dry Run Protection | Available as an add-on | Not available |
| Maintenance | Low — solid-state switching, PMC contactor | Higher — mechanical timer relay wears over time |
| Customization | Subtech offers custom panel manufacturing on request | Typically fixed configuration |
Downloads
Technical documentation for this model
Related Products
Applicable Standards & Design Considerations
- IEC/IS 60947: Low-voltage switchgear and controlgear — general design reference for contactors, starters and protective devices, where applicable to the components used.
- IS/IEC 60529: Enclosure ingress protection (IP) ratings — referenced for enclosure design where an IP rating is specified for a given model.