Subtech LogoSince 1998
Powermax 4G Series — Star Delta
Subtech Product

Powermax 4G Series — Star DeltaThree Phase Motor Starter · 4G / GSM

Get Best Price
Model Type
Powermax 4G Series — Star Delta · Three Phase Motor Starter
Operation
4G / GSM · Mobile-controlled Star Delta with MCB/MCCB
Rating Range
7.5 HP - 125 HP
Best Suited For
Star Delta · 4G/GSM

Smart motor control panel designed for smooth starting and remote operation of three-phase submersible and motor pumps. Combines 4G/mobile-based access with dependable protection, digital monitoring, and a durable panel design.

What is Powermax 4G Series — Star Delta?

Powermax 4G Series — Star Delta is a 4g / gsm three phase motor starter panel from Subtech (S S Power System), covering 7.5 HP to 125 HP. It is part of Subtech's motor control solutions range and is commonly used for induction motors, pumps, compressors and other industrial and agricultural machinery. Protection features include single phase protection, phase reversal protection, over voltage protection, under voltage protection, overload protection, under load protection, short circuit protection, dry run protection (optional).

Key Specifications at a Glance

Quick reference before you scroll through the full spec sheet

Product Series
Powermax 4G Series — Star Delta
Product Category
Motor Control Solutions
Operation
4G / GSM
Starter Type
Star Delta / 4G/GSM
Motor Phase
Three Phase
Rating Range
7.5 - 125 HP
Protection Type
Single Phase Protection, Phase Reversal Protection, Over Voltage Protection, Under Voltage Protection, Overload Protection, Under Load Protection, Short Circuit Protection, Dry Run Protection (Optional)
Best Suited For
Star Delta · 4G/GSM
Available Models
14 models
Add-ons
3 available

Why Choose Powermax 4G Series — Star Delta?

What actually matters when you put this on your line

Automated Operation

Reduces manual switching and operator error by handling the start-up sequence on its own.

Reduced Starting Current

Star-Delta switching lowers inrush current at start-up, protecting windings, cabling and upstream breakers.

Digital Monitoring

A digital display and settings make it easier to read status and adjust cut-offs without repeatedly opening the panel.

Multiple Motor Protections

Built-in protection against single phase protection, phase reversal protection, over voltage protection, under voltage protection reduces avoidable motor failures.

Wide HP Range

Covers 7.5 - 125 HP, so one series can standardise across multiple motor sizes on site.

Built for Industrial & Pump Applications

Designed for the duty cycles seen in pumps, compressors, HVAC systems and general industrial motor loads.

Custom Panel Manufacturing Support

Subtech can adapt enclosure size, ratings and add-ons to project-specific requirements on request.

Rust-Resistant, Field-Ready Enclosure

Powder-coated GI/GPSP enclosures are built for Indian site conditions — dusty factory floors, outdoor pump houses and agricultural sheds alike.

How Powermax 4G Series — Star Delta Works

Step-by-step operating sequence

  1. 1

    Motor Starts in Star Connection

    On the start command, the contactor connects the motor windings in Star, limiting inrush current.

  2. 2

    Starting Current Is Reduced

    The Star connection drops the line current to roughly a third of a direct-on-line start, reducing stress on the motor and supply.

  3. 3

    Timer/Control Logic Monitors the Transition

    An internal timer (or digital control logic on automatic models) tracks how long the motor has been running in Star.

  4. 4

    Starter Switches to Delta Connection

    Once the motor has picked up speed, the panel switches the winding connection to Delta for full running torque.

  5. 5

    Motor Runs at Full Load

    In Delta, the motor receives full line voltage across each winding and runs at rated output.

  6. 6

    Protection System Monitors Faults Continuously

    Single phasing, reverse phasing, voltage and overload protection continue monitoring the motor throughout the run.

How to Select the Correct Model

Match your motor's HP rating to the correct reference number

HPRef. No.kWRelay Range (A)ProtectionSize (mm)MRP
7.5 HPS4X75.510-25MCB350*400*125₹36,000
10 HPS4X107.515-35MCB350*400*125₹36,000
15 HPS4X151120-45MCB350*400*125₹37,900
20 HPS4X201525-50MCB350*400*125₹39,600
25 HPS4X2518.530-55MCCB350*455*125₹49,600
30 HPS4X30L2240-75MCCB350*455*125₹49,900
30 HPS4X302240-75MCCB350*455*125₹65,500
40 HPS4X403060-90MCCB430*510*150₹68,400
50 HPS4X503770-120MCCB600*450*190₹91,300
60 HPS4X604580-140MCCB600*450*190₹91,300
75 HPS4X755690-150MCCB650*500*200₹1,10,800
85 HPS4X8560120-185MCCB650*500*200₹1,19,500
100 HPS4X1007570-120 (H)MCCBOn Request
125 HPS4X1259080-140 (H)MCCBOn Request

Common Problems This Solves

Real failure modes on the motor side, and how this panel prevents them

High Starting Current

Star-Delta switching reduces inrush current at start-up compared to a direct-on-line start, easing stress on the motor, cabling and upstream breakers.

Motor Overheating

Sustained overload, phase and voltage faults raise winding temperature over time; the panel's built-in protections cut power before heat damages the insulation.

Single Phasing

Detects the loss of any one phase and cuts power before the motor overheats or burns its windings.

Over-Voltage Spikes

Cuts power when supply voltage rises above the safe band, protecting insulation and electronics.

Under-Voltage / Low Supply

Cuts power when voltage drops too low, preventing the motor from drawing excess current to compensate.

Motor Overload

Monitors running current and trips before sustained overload can overheat the motor.

Short Circuit / Wiring Fault

MCB/MCCB protection isolates the circuit immediately on a short circuit, protecting the panel and wiring.

Dry Running (Pump Losing Prime)

Optional dry-run protection stops the motor when there's no load/flow, preventing pump damage from running dry.

Frequent Tripping From Wrong Model Selection

Use the selection guide above to match your motor's HP and relay range to the correct reference number — an undersized relay setting is a common cause of nuisance tripping.

Description

Smart motor control panel designed for smooth starting and remote operation of three-phase submersible and motor pumps. Combines 4G/mobile-based access with dependable protection, digital monitoring, and a durable panel design.

Additional Information
  • Controlling & Monitoring via SMS, Call, WhatsApp, Web-App
  • Auto / Manual / Bypass Mode
  • GSM Auto Mode and GSM Manual Mode
  • Power resumption alert via SMS
  • Real-time fault alerts on mobile
  • Run-Hour Meter
  • All Fault Indicators
  • 4G connectivity built-in
  • Programmable protections
  • Smart digital display interface

Models & Pricing

14 models
Ref. No.HPkWRelay Range (A)Size (mm)Wt. (kg)ProtectionMRPStd. Pack
S4X77.55.510-25350*400*1257.5MCB₹36,0003
S4X10107.515-35350*400*1257.5MCB₹36,0003
S4X15151120-45350*400*1257.5MCB₹37,9003
S4X20201525-50350*400*1258.0MCB₹39,6003
S4X252518.530-55350*455*1259.2MCCB₹49,6003
S4X30L302240-75350*455*1259.3MCCB₹49,9003
S4X30302240-75350*455*1259.3MCCB₹65,5002
S4X40403060-90430*510*15013.2MCCB₹68,4002
S4X50503770-120600*450*19022.0MCCB₹91,3002
S4X60604580-140600*450*19022.5MCCB₹91,3002
S4X75755690-150650*500*20033.0MCCB₹1,10,8002
S4X858560120-185650*500*20038.0MCCB₹1,19,500
S4X1001007570-120 (H)MCCBOn Request
S4X1251259080-140 (H)MCCBOn Request
Prices are MRP in INR, ex-GST and ex-installation. Specifications subject to change without notice.

Protections

  • Single Phase Protection
  • Phase Reversal Protection
  • Over Voltage Protection
  • Under Voltage Protection
  • Overload Protection
  • Under Load Protection
  • Short Circuit Protection
  • Dry Run Protection (Optional)

Add-ons

  • Dry Run Charges: ₹890 charged extra
  • Remote Trip: ₹1150
  • Sensor set (2 pcs) for water level controlling: ₹2500
  • Note: Size and Weight are approximate

Who Should Buy Powermax 4G Series — Star Delta?

This product is ideal for the following users and industries

🏭

Industrial Units & Factories

Manufacturing plants, processing units, and industrial facilities requiring reliable motor control and automation solutions.

🌾

Agricultural & Farming

Farmers and agricultural businesses using water pumps, irrigation systems, and motor-driven equipment for daily operations.

🏗️

Contractors & Builders

Electrical contractors, panel builders, and construction professionals who need dependable motor starting solutions.

🏢

Commercial Establishments

Hotels, hospitals, offices, and commercial buildings with HVAC, lift, and pump motor control requirements.

Applications & Use Cases

Where you can use Powermax 4G Series — Star Delta effectively

1

Water Pump Motor Control

Submersible, centrifugal, and booster pump motor starting, protection, and automation for residential and commercial use.

2

Compressor & HVAC Systems

Air compressors, chillers, and HVAC blower motor control in factories, commercial buildings, and cold storage units.

3

Conveyor & Material Handling

Belt conveyors, rollers, and material handling equipment motors used in manufacturing and logistics.

4

Irrigation & Agriculture

Drip irrigation, sprinkler systems, and tube well motors for farms and agricultural land management.

5

Generator & ATS Panels

Auto transfer switch panels and generator motor control for seamless power backup solutions.

6

CNC & Machine Tools

Lathe machines, drilling machines, and CNC equipment requiring precise motor starting and protection.

Frequently Asked Questions

Common questions about Powermax 4G Series — Star Delta

What is the warranty on Powermax 4G Series — Star Delta?

Subtech provides a standard manufacturer warranty on this product. Warranty terms may vary based on the specific model and configuration. Contact our sales team for detailed warranty information.

Can I get a customized version of Powermax 4G Series — Star Delta?

Yes, Subtech specializes in custom panel manufacturing. We can modify specifications, ratings, enclosure types, and features as per your specific requirements. Share your needs through the quote form above.

What is the delivery time?

Standard models are typically available within 3-5 working days. Customized configurations may take 7-15 working days depending on complexity. We deliver across India.

Is installation support available?

Yes, Subtech provides installation guidance and technical support. For bulk orders, on-site commissioning support is also available. Our service team can assist with wiring diagrams and configuration.

Can I buy this product in bulk for my project?

Absolutely. We offer competitive bulk pricing for dealers, distributors, contractors, and project orders. Request a quote with your quantity for the best price.

Downloads

Technical documentation for this model

DatasheetAvailable on request
CatalogueAvailable on request
Wiring DiagramAvailable on request
Installation ManualAvailable on request
Technical SpecificationsAvailable on request

Related Products

Related Technical Articles

Applicable Standards & Design Considerations

  • IEC/IS 60947: Low-voltage switchgear and controlgear — general design reference for contactors, starters and protective devices, where applicable to the components used.
  • IS/IEC 60529: Enclosure ingress protection (IP) ratings — referenced for enclosure design where an IP rating is specified for a given model.