Subtech LogoSince 1998
Powermax 4G Series — DOL
Subtech Product

Powermax 4G Series — DOLThree Phase Motor Starter · 4G / GSM

Get Best Price
Model Type
Powermax 4G Series — DOL · Three Phase Motor Starter
Operation
4G / GSM · Mobile-controlled DOL with built-in protection
Rating Range
1 HP - 20 HP
Best Suited For
DOL · 4G/GSM

The Subtech PowerMax DOL Motor Control Panel is designed for reliable and efficient motor starting with built-in protection and mobile-based control. Ideal for users who need better protection, reliability, and smooth motor control.

What is Powermax 4G Series — DOL?

Powermax 4G Series — DOL is a 4g / gsm three phase motor starter panel from Subtech (S S Power System), covering 1 HP to 20 HP. It is part of Subtech's motor control solutions range and is commonly used for induction motors, pumps, compressors and other industrial and agricultural machinery. Protection features include single phase protection, phase reversal protection, over voltage protection, under voltage protection, overload protection, under load protection, short circuit protection, dry run protection (optional).

Key Specifications at a Glance

Quick reference before you scroll through the full spec sheet

Product Series
Powermax 4G Series — DOL
Product Category
Motor Control Solutions
Operation
4G / GSM
Starter Type
DOL / 4G/GSM
Motor Phase
Three Phase
Rating Range
1 - 20 HP
Protection Type
Single Phase Protection, Phase Reversal Protection, Over Voltage Protection, Under Voltage Protection, Overload Protection, Under Load Protection, Short Circuit Protection, Dry Run Protection (Optional)
Best Suited For
DOL · 4G/GSM
Available Models
8 models
Add-ons
Not applicable

Why Choose Powermax 4G Series — DOL?

What actually matters when you put this on your line

Automated Operation

Reduces manual switching and operator error by handling the start-up sequence on its own.

Digital Monitoring

A digital display and settings make it easier to read status and adjust cut-offs without repeatedly opening the panel.

Multiple Motor Protections

Built-in protection against single phase protection, phase reversal protection, over voltage protection, under voltage protection reduces avoidable motor failures.

Wide HP Range

Covers 1 - 20 HP, so one series can standardise across multiple motor sizes on site.

Built for Industrial & Pump Applications

Designed for the duty cycles seen in pumps, compressors, HVAC systems and general industrial motor loads.

Custom Panel Manufacturing Support

Subtech can adapt enclosure size, ratings and add-ons to project-specific requirements on request.

Rust-Resistant, Field-Ready Enclosure

Powder-coated GI/GPSP enclosures are built for Indian site conditions — dusty factory floors, outdoor pump houses and agricultural sheds alike.

Backed by Subtech's Sales & Service Network

25+ years of panel manufacturing and a pan-India dealer network stand behind every unit.

How Powermax 4G Series — DOL Works

Step-by-step operating sequence

  1. 1

    Start Command Given

    Pressing start (or an auto signal) energises the main contactor directly.

  2. 2

    Motor Connects Directly to Full Line Voltage

    The motor windings are connected straight across the supply — no reduced-voltage stage.

  3. 3

    Motor Accelerates to Full Speed

    The motor draws a higher inrush current for a short period while it comes up to speed.

  4. 4

    Motor Runs at Full Load

    Once up to speed, the motor runs at its rated current under normal load.

  5. 5

    Protection System Monitors Faults Continuously

    Overload, short-circuit and (where fitted) phase protection continue monitoring the motor throughout the run.

How to Select the Correct Model

Match your motor's HP rating to the correct reference number

HPRef. No.kWRelay Range (A)ProtectionSize (mm)MRP
1 HPD4X10.752-10300*225*110₹23,200
5 HPD4X53.75-20300*225*110₹23,200
7.5 HPD4X7L5.510-25300*225*110₹23,200
7.5 HPD4X75.510-25300*225*110₹24,500
10 HPD4X107.515-35300*225*110₹24,500
12.5 HPD4X129.320-40300*225*110₹24,900
15 HPD4X151120-45300*225*110₹27,300
20 HPD4X201525-50350*250*120₹31,500

Common Problems This Solves

Real failure modes on the motor side, and how this panel prevents them

Motor Overheating

Sustained overload, phase and voltage faults raise winding temperature over time; the panel's built-in protections cut power before heat damages the insulation.

Single Phasing

Detects the loss of any one phase and cuts power before the motor overheats or burns its windings.

Over-Voltage Spikes

Cuts power when supply voltage rises above the safe band, protecting insulation and electronics.

Under-Voltage / Low Supply

Cuts power when voltage drops too low, preventing the motor from drawing excess current to compensate.

Motor Overload

Monitors running current and trips before sustained overload can overheat the motor.

Short Circuit / Wiring Fault

MCB/MCCB protection isolates the circuit immediately on a short circuit, protecting the panel and wiring.

Dry Running (Pump Losing Prime)

Optional dry-run protection stops the motor when there's no load/flow, preventing pump damage from running dry.

Frequent Tripping From Wrong Model Selection

Use the selection guide above to match your motor's HP and relay range to the correct reference number — an undersized relay setting is a common cause of nuisance tripping.

Description

The Subtech PowerMax DOL Motor Control Panel is designed for reliable and efficient motor starting with built-in protection and mobile-based control. Ideal for users who need better protection, reliability, and smooth motor control.

Additional Information
  • Controlling & Monitoring via SMS, Call, WhatsApp, Web-App
  • Auto / Manual / Bypass Mode
  • GSM Auto Mode and GSM Manual Mode
  • Power resumption alert via SMS
  • Real-time fault alerts on mobile
  • Run-Hour Meter
  • All Fault Indicators
  • 4G connectivity built-in
  • Programmable protections
  • Smart digital display interface

Models & Pricing

8 models
Ref. No.HPkWRelay Range (A)Size (mm)Wt. (kg)MRPStd. Pack
D4X110.752-10300*225*1104.0₹23,2004
D4X553.75-20300*225*1104.0₹23,2004
D4X7L7.55.510-25300*225*1104.0₹23,2004
D4X77.55.510-25300*225*1104.3₹24,5004
D4X10107.515-35300*225*1104.3₹24,5004
D4X1212.59.320-40300*225*1104.3₹24,9004
D4X15151120-45300*225*1104.3₹27,3002
D4X20201525-50350*250*1205.5₹31,5002
Prices are MRP in INR, ex-GST and ex-installation. Specifications subject to change without notice.

Protections

  • Single Phase Protection
  • Phase Reversal Protection
  • Over Voltage Protection
  • Under Voltage Protection
  • Overload Protection
  • Under Load Protection
  • Short Circuit Protection
  • Dry Run Protection (Optional)

Who Should Buy Powermax 4G Series — DOL?

This product is ideal for the following users and industries

🏭

Industrial Units & Factories

Manufacturing plants, processing units, and industrial facilities requiring reliable motor control and automation solutions.

🌾

Agricultural & Farming

Farmers and agricultural businesses using water pumps, irrigation systems, and motor-driven equipment for daily operations.

🏗️

Contractors & Builders

Electrical contractors, panel builders, and construction professionals who need dependable motor starting solutions.

🏢

Commercial Establishments

Hotels, hospitals, offices, and commercial buildings with HVAC, lift, and pump motor control requirements.

Applications & Use Cases

Where you can use Powermax 4G Series — DOL effectively

1

Water Pump Motor Control

Submersible, centrifugal, and booster pump motor starting, protection, and automation for residential and commercial use.

2

Compressor & HVAC Systems

Air compressors, chillers, and HVAC blower motor control in factories, commercial buildings, and cold storage units.

3

Conveyor & Material Handling

Belt conveyors, rollers, and material handling equipment motors used in manufacturing and logistics.

4

Irrigation & Agriculture

Drip irrigation, sprinkler systems, and tube well motors for farms and agricultural land management.

5

Generator & ATS Panels

Auto transfer switch panels and generator motor control for seamless power backup solutions.

6

CNC & Machine Tools

Lathe machines, drilling machines, and CNC equipment requiring precise motor starting and protection.

Frequently Asked Questions

Common questions about Powermax 4G Series — DOL

What is the warranty on Powermax 4G Series — DOL?

Subtech provides a standard manufacturer warranty on this product. Warranty terms may vary based on the specific model and configuration. Contact our sales team for detailed warranty information.

Can I get a customized version of Powermax 4G Series — DOL?

Yes, Subtech specializes in custom panel manufacturing. We can modify specifications, ratings, enclosure types, and features as per your specific requirements. Share your needs through the quote form above.

What is the delivery time?

Standard models are typically available within 3-5 working days. Customized configurations may take 7-15 working days depending on complexity. We deliver across India.

Is installation support available?

Yes, Subtech provides installation guidance and technical support. For bulk orders, on-site commissioning support is also available. Our service team can assist with wiring diagrams and configuration.

Can I buy this product in bulk for my project?

Absolutely. We offer competitive bulk pricing for dealers, distributors, contractors, and project orders. Request a quote with your quantity for the best price.

Downloads

Technical documentation for this model

DatasheetAvailable on request
CatalogueAvailable on request
Wiring DiagramAvailable on request
Installation ManualAvailable on request
Technical SpecificationsAvailable on request

Related Products

Related Technical Articles

Applicable Standards & Design Considerations

  • IEC/IS 60947: Low-voltage switchgear and controlgear — general design reference for contactors, starters and protective devices, where applicable to the components used.
  • IS/IEC 60529: Enclosure ingress protection (IP) ratings — referenced for enclosure design where an IP rating is specified for a given model.