Subtech LogoSince 1998
Inbuilt Auto Phase Correction DOL
Subtech Product

Inbuilt Auto Phase Correction DOLThree Phase Motor Starter · Advanced DOL

Get Best Price
Model Type
Inbuilt Auto Phase Correction DOL · Three Phase Motor Starter
Operation
Advanced DOL · Auto-corrects phase sequence for safe 3-phase motor operation
Rating Range
5 HP - 15 HP
Best Suited For
DOL · Auto Phase Correction

Smart motor starter panel that automatically corrects phase sequence for safe and proper 3-phase motor operation.

What is Inbuilt Auto Phase Correction DOL?

Inbuilt Auto Phase Correction DOL is a advanced dol three phase motor starter panel from Subtech (S S Power System), covering 5 HP to 15 HP. It is part of Subtech's motor control solutions range and is commonly used for induction motors, pumps, compressors and other industrial and agricultural machinery. Protection features include overload and short-circuit protection.

Key Specifications at a Glance

Quick reference before you scroll through the full spec sheet

Product Series
Inbuilt Auto Phase Correction DOL
Product Category
Motor Control Solutions
Operation
Advanced DOL
Starter Type
DOL / Auto Phase Correction
Motor Phase
Three Phase
Rating Range
5 - 15 HP
Protection Type
As per model
Best Suited For
DOL · Auto Phase Correction
Available Models
5 models
Add-ons
Not applicable

Why Choose Inbuilt Auto Phase Correction DOL?

What actually matters when you put this on your line

Automated Operation

Reduces manual switching and operator error by handling the start-up sequence on its own.

Digital Monitoring

A digital display and settings make it easier to read status and adjust cut-offs without repeatedly opening the panel.

Wide HP Range

Covers 5 - 15 HP, so one series can standardise across multiple motor sizes on site.

Built for Industrial & Pump Applications

Designed for the duty cycles seen in pumps, compressors, HVAC systems and general industrial motor loads.

Custom Panel Manufacturing Support

Subtech can adapt enclosure size, ratings and add-ons to project-specific requirements on request.

Rust-Resistant, Field-Ready Enclosure

Powder-coated GI/GPSP enclosures are built for Indian site conditions — dusty factory floors, outdoor pump houses and agricultural sheds alike.

Backed by Subtech's Sales & Service Network

25+ years of panel manufacturing and a pan-India dealer network stand behind every unit.

How Inbuilt Auto Phase Correction DOL Works

Step-by-step operating sequence

  1. 1

    Start Command Given

    Pressing start (or an auto signal) energises the main contactor directly.

  2. 2

    Motor Connects Directly to Full Line Voltage

    The motor windings are connected straight across the supply — no reduced-voltage stage.

  3. 3

    Motor Accelerates to Full Speed

    The motor draws a higher inrush current for a short period while it comes up to speed.

  4. 4

    Motor Runs at Full Load

    Once up to speed, the motor runs at its rated current under normal load.

  5. 5

    Protection System Monitors Faults Continuously

    Overload, short-circuit and (where fitted) phase protection continue monitoring the motor throughout the run.

How to Select the Correct Model

Match your motor's HP rating to the correct reference number

HPRef. No.kWRelay Range (A)ProtectionSize (mm)MRP
5 HPDAP53.75-20350*400*125₹32,000
7.5 HPDAP75.510-25350*400*125₹32,000
10 HPDAP107.515-35350*400*125₹32,000
12.5 HPDAP129.320-40350*400*125₹33,750
15 HPDAP151120-45350*400*125₹33,750

Common Problems This Solves

Real failure modes on the motor side, and how this panel prevents them

Frequent Tripping From Wrong Model Selection

Use the selection guide above to match your motor's HP and relay range to the correct reference number — an undersized relay setting is a common cause of nuisance tripping.

Description

Smart motor starter panel that automatically corrects phase sequence for safe and proper 3-phase motor operation.

Additional Information
  • Microcontroller based system
  • Wide voltage range: 200-480 VAC
  • Auto / Manual / Bypass mode
  • Start / Stop push button control
  • Adjustable start delay
  • Digital voltmeter, ammeter and run-hour display
  • LED status and fault indications
  • Over / under voltage protection
  • Overload protection
  • Rust-free GI sheet enclosure
  • Compact wall-mounted design
  • Heavy-duty terminals for secure wiring
  • Inbuilt MCB / MCCB protection
  • Low maintenance and reliable performance

Models & Pricing

5 models
Ref. No.HPkWRelay Range (A)Size (mm)Wt. (kg)MRP
DAP553.75-20350*400*1255.0₹32,000
DAP77.55.510-25350*400*1255.0₹32,000
DAP10107.515-35350*400*1255.0₹32,000
DAP1212.59.320-40350*400*1255.0₹33,750
DAP15151120-45350*400*1255.0₹33,750
Prices are MRP in INR, ex-GST and ex-installation. Specifications subject to change without notice.

Who Should Buy Inbuilt Auto Phase Correction DOL?

This product is ideal for the following users and industries

🏭

Industrial Units & Factories

Manufacturing plants, processing units, and industrial facilities requiring reliable motor control and automation solutions.

🌾

Agricultural & Farming

Farmers and agricultural businesses using water pumps, irrigation systems, and motor-driven equipment for daily operations.

🏗️

Contractors & Builders

Electrical contractors, panel builders, and construction professionals who need dependable motor starting solutions.

🏢

Commercial Establishments

Hotels, hospitals, offices, and commercial buildings with HVAC, lift, and pump motor control requirements.

Applications & Use Cases

Where you can use Inbuilt Auto Phase Correction DOL effectively

1

Water Pump Motor Control

Submersible, centrifugal, and booster pump motor starting, protection, and automation for residential and commercial use.

2

Compressor & HVAC Systems

Air compressors, chillers, and HVAC blower motor control in factories, commercial buildings, and cold storage units.

3

Conveyor & Material Handling

Belt conveyors, rollers, and material handling equipment motors used in manufacturing and logistics.

4

Irrigation & Agriculture

Drip irrigation, sprinkler systems, and tube well motors for farms and agricultural land management.

5

Generator & ATS Panels

Auto transfer switch panels and generator motor control for seamless power backup solutions.

6

CNC & Machine Tools

Lathe machines, drilling machines, and CNC equipment requiring precise motor starting and protection.

Frequently Asked Questions

Common questions about Inbuilt Auto Phase Correction DOL

What is the warranty on Inbuilt Auto Phase Correction DOL?

Subtech provides a standard manufacturer warranty on this product. Warranty terms may vary based on the specific model and configuration. Contact our sales team for detailed warranty information.

Can I get a customized version of Inbuilt Auto Phase Correction DOL?

Yes, Subtech specializes in custom panel manufacturing. We can modify specifications, ratings, enclosure types, and features as per your specific requirements. Share your needs through the quote form above.

What is the delivery time?

Standard models are typically available within 3-5 working days. Customized configurations may take 7-15 working days depending on complexity. We deliver across India.

Is installation support available?

Yes, Subtech provides installation guidance and technical support. For bulk orders, on-site commissioning support is also available. Our service team can assist with wiring diagrams and configuration.

Can I buy this product in bulk for my project?

Absolutely. We offer competitive bulk pricing for dealers, distributors, contractors, and project orders. Request a quote with your quantity for the best price.

Downloads

Technical documentation for this model

DatasheetAvailable on request
CatalogueAvailable on request
Wiring DiagramAvailable on request
Installation ManualAvailable on request
Technical SpecificationsAvailable on request

Related Products

Related Technical Articles

Applicable Standards & Design Considerations

  • IEC/IS 60947: Low-voltage switchgear and controlgear — general design reference for contactors, starters and protective devices, where applicable to the components used.
  • IS/IEC 60529: Enclosure ingress protection (IP) ratings — referenced for enclosure design where an IP rating is specified for a given model.